Intertherm Blinking Error 2

______________________________________________________________________ I have a Intertherm furnace in the 98 modular home I live in.It worked fine till my gas was turned off but when I had the gas turned back on about 2 months later the furnace will not work.It is blinking error 2. The a/c is working just not the heat and with winter being here we need heat :) Any Ideas? Thanks In Advance Stacey Mom To: Keira Braeleigh 8-15-03 Piston Lee 3-19-99 Gabriel Irene 10-28-00 to 10-29-00 Replies: Wolfe “Re(1):Intertherm Blinking Error 2″ , posted Wed 3 Nov 21:49 ______________________________________________________________________ My guess is that the furnace tried to light with the gas off and went into lock-out. Try turning the power off to the furnace, at the circuit breaker, and see what happens. Sbrown “Re(2):Intertherm Blinking Error 2″ , posted Thu 4 Nov 13:50 ______________________________________________________________________ Tried that but it didnt work :( Any more Ideas? THe furnace says that error code means: “The control did not receive the signal that the inducer centrilfigal switch has closed within the time” but I have no clue what that means. Thanks Again, Stacey Stacey Mom To: Keira Braeleigh 8-15-03 Piston Lee 3-19-99 Gabriel Irene 10-28-00 to 10-29-00 xenos Webmaster “Re(3):Intertherm Blinking Error 2″ , posted Thu 4 Nov 18:02 ______________________________________________________________________ That means there may be a problem with the venting. Check it and make sure it’s clear. Xenos. The best way to escape a problem is to solve it. Sbrown “Re(4):Intertherm Blinking Error 2″ , posted Thu 4 Nov 18:56 ______________________________________________________________________ I am going to have someone come over tomorrow to check the vent on the roof.I dont see anything clogged on the inside but the blower is mighty dusty,could that be the problem? If so I’ll see if I can get it out of there and blow it out with my uncles air compressor. THanks Again, Stacey Stacey Mom To: Keira Braeleigh 8-15-03 Piston Lee 3-19-99 Gabriel Irene 10-28-00 to 10-29-00 xenos Webmaster “Re(5):Intertherm Blinking Error 2″ , posted Thu 4 Nov 19:08 ______________________________________________________________________ Does the venter motor run ? Xenos. The best way to escape a problem is to solve it. Sbrown “Re(6):Intertherm Blinking Error 2″ , posted Fri 5 Nov 18:26 ______________________________________________________________________ Got it fixed….I re-done what Wolfe said but had to reset the breaker 4x before the black motor started working(connects to the pipe that goes outside I beleive). THamks Again, Stacey Stacey Mom To: Keira Braeleigh 8-15-03 Piston Lee 3-19-99 Gabriel Irene 10-28-00 to 10-29-00

Comments are closed.